Damage to the dispenser is as follows:
1. water coming out through the valve is not cool blue color
- Check the thermostat is located on the back of the dispenser, is positioned on the low?
- if yes, turn the thermostat to the right / high.
- Check the thermostat terminals on two legs, is there a resistance / ohm for electrical current can flow to the compressor?
- Check compressor, whether to operate or not?
if it does not operate check the compressor relay, overload the compressor and wires leading to the compressor.
- Freon leak check on all system piping connections.
2. water out of the bottom of the dispenser
- Check the rubber seal that is on the faucet.
- Check out the THREAD faucets and faucet in the connection, if a leak?
- Check, if the hot water tubes located at the center of a leak?
- Check the hose for draining water that is at the bottom of the tube of hot water, if ruptured or leaking?
3. Water coming out of the faucet is not red hot at all
- Check, whether the heater heaters were damaged, with the tester to measure both the position of the cable terminal on the ohm scale.
- Check, overload on the hot water cylinder, if there is resistance / ohm electrical current to flow.
- Also check the wires leading to the heater heater is broken or frayed? and check the switch on-off heater on the back of the dispenser, if the position on?